Chapter 11: The OptiFiber Pro OTDR Module
OTDR Results
367
Tap the settings you want. You can scroll some columns to see
more settings. Table 12 on page 312 gives descriptions of the
settings.
Select the wavelengths to use for the test.
Tap CURRENT to see the settings the tester used for the last test.
The SAVE SETUP button lets you save your settings:
Note
The SAVE SETUP button does not show if the
module selected in the test setup does not match
the installed module. For example, the button does
not show if the OptiFiber Pro - Quad OTDR module
is installed, but the active test setup is for an
OptiFiber Pro - Multimode OTDR or OptiFiber Pro -
Singlemode OTDR module.
Active: The tester saves the settings in the active test setup, and
changes the active Test Type to Manual.
New: The tester saves the settings in a new Manual test setup
that is added to the project. The tester uses the Manual setup
until you save the results or exit the results screen then start a
test from the home screen. Then the tester uses the test setup it
had before you changed the OTDR settings.
If you save your settings in a new test setup:
The tester uses your settings until you save the results or exit the
results screen then start a test from the home screen. Then the
tester uses the test setup it had before you changed the settings.
If you do not save your settings:
The tester uses your settings until you save the results or exit the
results screen then start a test from the home screen. Then the
tester uses the test setup it had before you changed the settings.
Tap TEST or press to do a test with the settings you
selected.