Versiv Series Cabling Certification Product Family
Technical Reference Handbook
406
4 On the TEST SETUP screen, tap SAVE when your test setup is
completed.
5 On the CHANGE TEST screen, make sure the button next to
the test is selected, then tap USE SELECTED.
Note
For all Test Types
except FaultMap and
FiberInspector, you can use the SETUP button on
the TRACE screen to change some OTDR settings
manually after a test. See “How to Quickly
Change OTDR Settings After a Test” on page 446.
Table 15. Settings for HDR OTDR Tests
Module Select the OptiFiber Pro module you will use.
To select a different module, tap the Module panel on the
TEST SETUP screen, then tap a module.
Test Type When you turn on the tester, the Test Type shows the test
that was last selected.
Auto PON OTDR: The tester automatically selects settings
that give you the best view of the events on PON links. The
tester automatically uses the DISCOVER function to locate
splitters and identify their ratios. This mode is the easiest
to use and is the best choice for most applications. To see
the settings the tester used for a test, tap SETUP on the
trace screen, then tap CURRENT.
Note
For links that have splitters with 1:64, 2:64, 1:128,
or 2:128 ratios, use a Manual PON OTDR test.
Manual PON ODTR: This mode lets you select settings to
control the test parameters for the trace. You can also
enter the ratios of splitters that you know are on the link,
or use the DISCOVER function to locate splitters and
identify their ratios. If you do not enter splitter ratios, the
tester identifies splitters as large loss events. Manual
settings are described in this table.
-continued-