Chapter 17: Use Projects
Tutorial: Make a New Project
527
Select Media: Select the type of module, Copper or Fiber, that
you will use when you use this ID set. For Fiber, also select one or
more fiber tests.
Notes
You can use an ID set only for results from the
media type you selected under Select Media.
The Select Media section does not show for ID sets
that do not have a Last ID. You can use these ID sets
for copper or fiber results.
Tap IMPORT to use an ID set that you downloaded to the tester
from LinkWare PC software.
Tap REVIEW to see the CABLE ID REVIEW screen, which shows
the ID set an the total number of IDs. See “How to Make ID Sets”
on page 548.
Note
The REVIEW button is not available if you do not
enter a Last ID.
SAVE: To save the ID set, tap SAVE.
When you select Fiber media for tests that use a CertiFiber Pro
or OptiFiber Pro module, select the tests that are necessary for
each fiber in the ID set.
For example, you can specify that you must do a Loss/Length
test and a FiberInspector test for each ID. After you do both
tests for all the IDs in the set, the tester shows 100% Tested on
the home screen. If no IDs include FiberInspector results, the
tester shows 50%. To see the IDs that need FiberInspector
results, select a FiberInspector test in the project, then look at
the list under FiberInspector IDs Untested on the CHANGE ID
screen (item
in Figure 199).