Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
504
Copyright 2011 FUJITSU LIMITED P2X0-1090-02ENZ0
• Specify Storage System Name for HELO/EHLO Announcement when Sending Mail
Select "Specify" or "Do not specify" for the ETERNUS DX Disk storage system name
for HELO/EHLO announcement when sending mail.
When "Specify" is selected, enter the domain.
The following input condition applies:
- 1 - 63 alphanumeric characters and symbols
The domain of the HELO/EHLO Announcement must be specified in the mail protocol.
If "Do not specify" has been selected, E-mails are sent using the strings after the "@" of
the sender mail addresses as domains.
If the mail server does not allow using the section after the "@" of the sender mail
address as the domain, select "Specify" and input the appropriate domain.
● Time Information
• SMTP Response Timeout (sec.)
Enter the timeout limit when using SMTP connection.
The following input condition applies:
- Numeric characters ("1" - "3600")
• SMTP Retry Count
Enter the retry number of SMTP.
The following input condition applies:
- Numeric characters ("1" - "60")
• SMTP Retry Interval (sec.)
Enter the intervals for retrying SMTP.
The following input condition applies:
- Numeric characters ("1" - "3600")
• HTTP Timeout (sec.)
Enter the timeout limit when using HTTP connection.
The following input condition applies:
- Numeric characters ("1" - "3600")
• HTTP Retry Count
Enter the retry number of HTTP.
The following input condition applies:
- Numeric characters ("1" - "60")
• HTTP Retry Interval (sec.)
Enter the intervals for retrying HTTP.
The following input condition applies:
- Numeric characters ("1" - "3600")
• Queue Time before Sending Mails (msec.) (only when POP Before SMTP authentica-
tion is enabled)
Enter the waiting time for sending mail.
The following input condition applies:
- Numeric characters ("1" - "3600")
The time information settings do not normally require
modification.
If changing the default value, select the "Change following Timing
Parameter items" checkbox.