CX2550 M1 Upgrade and Maintenance Manual 143
Processors
8.2.6.3 Installing the heat sinks
Figure 51: Installing the processor heat sinks
Ê Carefully seat the heat sink on the four threaded holes as shown.
V CAUTION!
Ensure that the screws on the heat sink are properly seated on the
threaded holes (see circles).
Ensure that the heat sink cooling fins match the direction of the
airflow!
I To avoid inclining of the heat sink carefully press on the middle of the
heat sink.
Ê Fasten the four captive screws on the heat sink in a crossover pattern
according to the numbering (screw torque: 1.0 Nm, not applicable for the
Japanese market).