EasyManuals Logo

Fujitsu PRIMERGY CX2550 M1 Upgrade And Maintenance Manual

Fujitsu PRIMERGY CX2550 M1
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
74 Upgrade and Maintenance Manual CX2550 M1
Basic software procedures
5.2.8 Verifying the memory mode
If a memory module fails, the server will reboot and the defective module will be
disabled. As a result, the current operation mode may no longer be available
due to a lack of identical memory module pairs. In this case, the operation mode
will automatically revert to Independent Channel Mode.
I For detailed information on memory operation modes available for your
server, refer to section "Operation modes" on page 120.
After replacing the defective module(s) the memory operation mode is
automatically reset to its original state. It is recommended to verify that the
operation mode has been correctly.
Ê Enter the BIOS.
Ê Select the Advanced menu.
Ê Under Memory Status verify that none of the memory modules are marked as
Failed.
Ê Save your changes (if applicable) and exit the BIOS.
I For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.

Table of Contents

Other manuals for Fujitsu PRIMERGY CX2550 M1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY CX2550 M1 and is the answer not in the manual?

Fujitsu PRIMERGY CX2550 M1 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY CX2550 M1
CategoryServer
LanguageEnglish

Related product manuals