CX2550 M1 Upgrade and Maintenance Manual 73
Basic software procedures
5.2.7 Enabling replaced components in the system BIOS
When a processor, an expansion card, or a memory module fails, the defective
component will be set to Disabled or Failed in the system BIOS. The server will
then reboot with only the intact hardware components remaining in the system
configuration. After replacing the defective component, it needs to be re-
enabled in the system board BIOS.
Ê Enter the BIOS.
Ê Select the Advanced menu.
Ê Select the status menu of the desired component:
Processors: CPU Status
I This option is only available for multi-processor systems.
Memory: Memory Status
Expansion cards: PCI Status
Ê Reset replaced components to Enable.
Ê Save your changes and exit the BIOS.
I For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.