64 Upgrade and Maintenance Manual CX2550 M1
Basic software procedures
Flash Memory Recovery Mode
I For the Japanese market, follow the instructions provided separately.
Ê Prepare a bootable USB stick as described in section "Flash BIOS update"
on page 61.
Ê Switch off the system and disconnect the power plug.
Ê Open the chassis and switch on "Recovery" (BIOS-RCV) using the jumper /
DIP switch (X5-6) on the system board.
Ê Reconnect the power plug.
Ê Boot the system from the inserted bootable USB stick.
Ê Change the directory with cd DOS and start the Flash BIOS Update with the
command DosFlash. Then follow the instructions on the screen.
Ê Observe the update process on the screen, until it is finished. The recovery
update may take several minutes.
V CAUTION!
Do not interrupt the BIOS flash process after it has started. If the
process is interrupted, the system BIOS may be permanently
corrupted.
Ê Switch off the system and disconnect the power plug.
Ê Remove the USB stick.
Ê Return the "Recovery" (BIOS-RCV) jumper / DIP (X5-6) switch which have
been changed to the initial position.
Ê Reconnect the power plug and switch on the system.
Ê The system will be booted with the new BIOS revision.
Ê Check the settings in the BIOS setup utility. If necessary, reconfigure the
settings again.

Table of Contents

Other manuals for Fujitsu PRIMERGY CX2550 M1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY CX2550 M1 and is the answer not in the manual?

Fujitsu PRIMERGY CX2550 M1 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY CX2550 M1
CategoryServer
LanguageEnglish

Related product manuals