Chapter 2 Fault Isolation 2-23
2.6.2.2 fmdump -e Command
To get information of the errors that caused this failure you can use the -e option, as
shown in the following example.
2.6.3 Using the fmadm faulty Command
The fmadm faulty command can be used by administrators and service personnel
to view and modify system configuration parameters that are maintained by the
Oracle Solaris fault manager. The command is primarily used to determine the status
of a component involved in a fault, as shown in the following example.
The PCI device is degraded and is associated with the same UUID as seen above. You
might also see “faulted” states.
2.6.3.1 fmadm repair Command
If fmadm faulty occurs, the faulty FRU (CPU, memory, or I/O unit) is replaced,
and then the fmadm repair command needs to be executed to clear FRU
information on the domain. If the fmadam repair command is not executed, error
messages continue to be output.
XSCF> fmdump -e
TIME CLASS
Oct 03 13:52:48.9532 ereport.fm.fmd.module
Oct 03 13:52:48.9610 ereport.fm.fmd.module
Oct 03 13:52:48.9674 ereport.fm.fmd.module
Oct 03 13:52:48.9738 ereport.fm.fmd.module
# fmadm faulty
STATERESOURCE / UUID
-------- --------------------------------------------------------
degraded dev:////pci@1e,600000
0ee65618-2218-4997-c0dc-b5c410ed8ec2
# fmadm repair
0ee65618-2218-4997-c0dc-b5c410ed8ec2

Table of Contents

Other manuals for Fujitsu SPARC Enterprise M5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC Enterprise M5000 and is the answer not in the manual?

Fujitsu SPARC Enterprise M5000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC Enterprise M5000
CategoryServer
LanguageEnglish

Related product manuals