8-22 SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010
8.4.6 Removing the I/O Unit DC-DC Converter Riser
1. Loosen the two screws at the front of the I/O unit using a No. 2 screwdriver
(
FIGURE 8-14).
2. Push the I/O unit cover slightly forward and then pull the front of the cover up
to remove the cover from the I/O unit.
3. Loosen the three screws that hold the metal bracket in place and tilt the bracket
towards the front of the I/O unit to expose the inside of the I/O unit.
The bracket has a circuit board and cable connected to it. It is not necessary to
remove the entire bracket.
4. Pull the DC-DC converter riser from the socket (
FIGURE 8-14).
Determine if your server currently has a label installed on the I/O unit DC-DC
converter (DDC_B#0).
â–  If your server does not have a label covering part of the I/O unit DC-DC
converter, go to Step 5.
â–  If your server does have a label covering part of the I/O unit DC-DC converter,
start from one corner of the label and peel the label free of the I/O unit DC-DC
converter.
5. Disengage the DC-DC converter from the slot in the DC-DC converter riser or
DC-DC converter retainer and place them both on the ESD mat.

Table of Contents

Other manuals for Fujitsu SPARC Enterprise M5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC Enterprise M5000 and is the answer not in the manual?

Fujitsu SPARC Enterprise M5000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC Enterprise M5000
CategoryServer
LanguageEnglish

Related product manuals