EasyManua.ls Logo

Fujitsu SPARC Enterprise M5000

Fujitsu SPARC Enterprise M5000
310 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 10 Fan Modules Replacement 10-7
10.1.5 Accessing the 172-mm Fan Module
1. From the XSCF Shell prompt, use the replacefru command to disable the fan
to be removed.
The replacefru command is menu-driven. replacefru will continue while the
fan is removed and then test the fan. Refer to Section 4.3.1, “Removing and Replacing
a FRU” on page 4-7 for more information.
Caution To prevent the equipment rack from tipping over, you must deploy the
antitilt feature, if applicable, before you slide the server out of the equipment rack.
Note When drawing out the M4000/M5000 Server to the front, release the cable tie
holding the PCI cables on the rear of the server.
2. Deploy the rack’s antitilt features (if applicable) and slide the server out of the
equipment rack.
See Section 5.1.1, “Sliding the Server Out of the Equipment Rack” on page 5-2.
Caution Use proper ESD grounding techniques when handling components. See
Section 1.1, “Safety Precautions” on page 1-1.
XSCF> replacefru

Table of Contents

Other manuals for Fujitsu SPARC Enterprise M5000

Related product manuals