Chapter 10 Fan Modules Replacement 10-7
10.1.5 Accessing the 172-mm Fan Module
1. From the XSCF Shell prompt, use the replacefru command to disable the fan
to be removed.
The replacefru command is menu-driven. replacefru will continue while the
fan is removed and then test the fan. Refer to Section 4.3.1, “Removing and Replacing
a FRU” on page 4-7 for more information.
Caution To prevent the equipment rack from tipping over, you must deploy the
antitilt feature, if applicable, before you slide the server out of the equipment rack.
Note When drawing out the M4000/M5000 Server to the front, release the cable tie
holding the PCI cables on the rear of the server.
2. Deploy the rack’s antitilt features (if applicable) and slide the server out of the
equipment rack.
See Section 5.1.1, “Sliding the Server Out of the Equipment Rack” on page 5-2.
Caution Use proper ESD grounding techniques when handling components. See
Section 1.1, “Safety Precautions” on page 1-1.
XSCF> replacefru

Table of Contents

Other manuals for Fujitsu SPARC Enterprise M5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC Enterprise M5000 and is the answer not in the manual?

Fujitsu SPARC Enterprise M5000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC Enterprise M5000
CategoryServer
LanguageEnglish

Related product manuals