Chapter 2 Fault Isolation 2-5
The hardware configuration and the status of each hardware component can be
checked from the maintenance terminal using eXtended System Control Facility
(XSCF) Shell commands, as shown in the following table.
Also some conditions can be checked based on the On or blinking state of the
component LEDs (see
TABLE 2-3).
2.2.1.1 Checking the Hardware Configuration
Login authority is required to check the hardware configuration. The following
procedure for these checks can be made from the maintenance terminal:
1. Log in with the account of the XSCF hardware maintenance engineer.
2. Type showhardconf.
The showhardconf command prints the hardware configuration information to
the screen. See the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User’s Guide for more detailed information.
TABLE 2-1 Commands for Checking Hardware Configuration
Command Description
showhardconf Displays hardware configuration.
showstatus Displays the status of a component. This command is used when
only a faulty component is checked.
showboards Displays the status of devices and resources.
showdcl Displays the hardware resource configuration information of a
domain.
showfru Displays the setting information of a device.
XSCF> showhardconf

Table of Contents

Other manuals for Fujitsu SPARC Enterprise M5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC Enterprise M5000 and is the answer not in the manual?

Fujitsu SPARC Enterprise M5000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC Enterprise M5000
CategoryServer
LanguageEnglish

Related product manuals