Chapter 2 Fault Isolation 2-21
2.6 Using the Diagnostic Commands
After the message in TABLE 2-7 is displayed, you might desire more information about
the fault. For complete information about troubleshooting commands, refer to the
Oracle Solaris 10 man pages or the XSCF Shell man pages. This section describes
some details of the following commands:
showlogs
fmdump
fmadm
fmstat
2.6.1 Using the showlogs Command
The showlogs command displays the contents of a specified log in order of time
stamp starting with the oldest date. The showlogs command displays the following
logs:
error log
power log
event log
temperature and humidity record
monitoring message log
console message log
panic message log
IPL message log
An example of the showlogs output.
XSCF> showlogs error
Date: Oct 03 17:23:11 UTC 2006 Code: 80002000-ccff0000-0104340100000000
Status: Alarm Occurred: Oct 03 17:23:10.868 UTC 2006
FRU: /FAN_A#0
Msg: Abnormal FAN rotation speed. Insufficient rotation
XSCF>