Chapter 4 FRU Replacement Preparation 4-13
Caution – There is an electrical hazard if the power cords are not disconnected. All
power cords must be disconnected to completely remove power from the server.
4.4.2 Powering the Server On Using Software
1. Make sure that the server has enough power supply units to run the desired
configuration.
2. Connect all power cables to the input power source.
3. Make sure the XSCF STANDBY LED on the operator panel is On.
4. Turn the keyswitch on the operator panel to the desired mode position (Locked
or Service).
5. Log into the XSCF Shell and type the poweron command.
Refer to the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
User’s Guide for details.
6. After a delay the following activities occur:
â–  The operator panel POWER LED lights.
â–  The system executes the power-on self-test (POST).
Then, the server is completely powered on.
Note – If the Oracle Solaris automatic booting is set, use the sendbreak -d
domain_id command after the display console banner is displayed but before the
system starts booting the operating system to get the ok prompt.
XSCF> poweron -a

Table of Contents

Other manuals for Fujitsu SPARC Enterprise M5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC Enterprise M5000 and is the answer not in the manual?

Fujitsu SPARC Enterprise M5000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC Enterprise M5000
CategoryServer
LanguageEnglish

Related product manuals