Section 4
4-80 © Copyright 2009 GBC. All rights reserved. Advanced Punch Service Manual
4.14Diverter Gate Solenoid Adjustment
Procedure
Figure 4.97 Solenoid Link Stopper
When looking into the paper entrance chute on the AdvancedPunch, the leading
edge of the diverter gate should not be visible.
Figure 4.98 Diverter Gate
Move Link Stopper to left.
Then tighten screws
Diverter Gate
Leading Edge