SC201(1900A/1903A) Appendix1
53
Work Clamp
Foot Position
Error
The work clamp foot is not in the proper
position.
Turn OFF the power and
check whether X9 circuit is
disconnected or loose.
Thread Clamp
Position Error
The needle thread clamp device is not in
the proper position.
Turn OFF the power switch
and check whether CZ026 is
disconnected or loose.
Encoder Cable
Not Connected
Not be able to detect ADTC signal
Turn OFF the power and
check whether X5 circuit is
disconnected or loose.
Communication
between the
Main Board and
Step Driver
Board Error
Communication interferes.
Turn OFF the power and
remove the cause.
Overcurrent of
Main Servo
Motor
Make sure that the machine
is not locked, and then check
weather the Encoder cable is
connected well.
Power source voltage is beyond the
specified value
Check the power source
voltage
Power source voltage is short
Check the power source
voltage
Main Servo
Motor Driver
Trouble
Error form the driver is detected.
Turn OFF the power and
turn ON the power again
after some time.
Stepping Motor
power source
trouble.
The current of the stepping driver board
is over current.
Turn OFF the power and
turn ON the power again
after some time.
Turn OFF the power and
turn ON the power again
after some time.
Main Servo
Motor Out of
Control
Main Servo Motor Out of Control
Turn OFF the power and
turn ON the power again
after some time.
X origin sensor does not change
Turn OFF the power supply
and check whether X9
coupling is disconnected or
loose.
Y origin sensor does not change
Turn OFF the power supply
and check whether X9
coupling is disconnected or
loose.