6-6
Setting of the Initial Down Force
The initial down-force setting is effective when tangential mode is selected.
tangential mode is generally used for the cutting of thick media. With thick lm, additional time is required for the
cutter blade to penetrate the media fully, even when the necessary cutting force is applied.
The cutting operation starts before the cutter blade has fully penetrated the media, causing uncut sections to be left.
When the initial down force is specied, this force is used as the cutting force immediately after the lowering of the
tool when tangential mode is selected, enabling the cutter blade to penetrate the media rapidly. (As an example,
if the cutting force is 25 and the initial down force is 4, for example, the cutting force applied immediately after the
pen is lowered will be 29)
The upper limit for added value is 39.
Operation
Supplement
Condition No.1 is pen specic. When setting
up tool conditions for the cutter plunger, please
choose from Condition No.2 to Condition
No.8 under "Selecting the Tool Condition". For
more information, see "2.10 Selecting Tool
Condition"
P. 2-2 9
.
1 Press the [COND/TEST] key.
CONDITION setting screen (1/3) is displayed.
2 Press the POSITION ( ) key.
CONDITION setting screen (3/3) is displayed.
3 Press the [2] key (INITIAL DOWN FORCE).
INITIAL DOWN FORCE setting screen is displayed.
4
Press the POSITION (
) key and select the CONDITION
No.
Supplement
Setting range is from 0 to 20.
5 Press the POSITION ( ) key and increase or decrease the
setting value.
Supplement
It will return to CONDITION screen (3/3)
without changing the settings when you press
the POSITION ( ) key (CANCEL).
6 Conrm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to CONDITION setting screen (3/3).
7 Press the [COND/TEST] key.
It will return to default screen.