2-34
Setting the Speed
Set the speed of the tool that is used in each of the condition numbers.
Setting range: 1 to10 (in 1 cm/s increment), 10 to 60 (in 5 cm/s increment)
Operation
Supplement
Please select Condition No.1 under "Selecting
the Tool Conditions" when setting up tool
conditions for the pen plunger, and select from
Condition No.2 to Condition No.8 when setting
up the tool conditions for the cutter plunger.
For more information, see "2.10 Selecting Tool
Condition"
P. 2-2 9
.
1 Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/3) is displayed.
Supplement
It will return to CONDITION screen (1/3)
without changing the settings when you press
the [4] key (CANCEL) .
2 Press the [3] key (SPEED) .
SPEED setting screen is displayed.
* Display may vary depending on the selected tool condition number.
3 Press the POSITION (
) key and select the tool condition
number (CONDITION No.) .
Supplement
Guideline to set speed
See "Setting the Tool Condition"
P. 2- 3 0
.
4 Press the POSITION ( ) key and increase or decrease the
setting value.
5 Confirm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to CONDITION screen (1/3).
6 Press the [COND/TEST] key.
It will return to default screen.