EasyManua.ls Logo

GRAPHTEC CE6000-120AP - Setting the Force

GRAPHTEC CE6000-120AP
227 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-35
Setting the Force
Set the cutting force that is used in each of the condition numbers.
Setting range: Condition No.1: 1 to 31
Condition No.2 to No.8: 1 to 38
Operation
Supplement
Perform the settings in Normal mode.
Supplement
Please select Condition No.1 under "Selecting
the Tool Conditions" when setting up tool
conditions for the pen plunger, and select from
Condition No.2 to Condition No.8 when setting
up the tool conditions for the cutter plunger.
For more information, see "2.10 Selecting Tool
Condition"
P. 2-2 9
.
1 Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/3) is displayed.
Supplement
It will return to CONDITION screen (1/3)
without changing the settings when you press
the [4] key (CANCEL) .
2 Press the [4] key (FORCE).
FORCE setting screen is displayed.
* Display may vary depending on the selected condition number.
3 Press the POSITION (
) key and select the condition
number (CONDITION No.).
Supplement
Guideline to set force
See "Setting the Tool Condition"
P. 2- 3 0
.
4 Press the POSITION ( ) key and increase or decrease the
setting value.
5 Conrm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to CONDITION screen (1/3).
6 Press the [COND/TEST] key.
It will return to default screen.