2-31
Setting the Tool
Set the type and offset value of the tool that is used in each of the tool condition numbers.
Condition No.1 applies specically to use of the pen plunger for the either oil-based ballpoint pen or water based
ber-tip pen.
Condition No.2 to No.8 applies specically to the use of the cutter plunger.
Setting Condition No.1 (Pen plunger specic)
Operation
Supplement
Please select Condition No.1 under "Selecting
the Tool Conditions" when setting up tool
conditions for the pen plunger, and choose
"Condition No.2" to "Condition No.8" when
setting up the tool conditions for the cutter
plunger. For more information, see "2.10
Selecting Tool Condition"
P. 2-2 9
.
1 Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/3) is displayed.
Supplement
It will return to CONDITION screen without
changing the settings when you press the
POSITION (
) key (CANCEL).
2 Press the [2] key (TOOL).
TOOL setting screen is displayed.
3 Press the [1] key.
CONDITION No. selection screen is displayed.
* Display may vary depending on the selected condition number.
4 Press the POSITION ( ) keys to select the Condition No. of
the Tool/Offset you wish to change.
From here, select "Condition No.1"
5 Conrm the setting and press the POSITION ( ) key
(PREVIOUS) .
CONDITION No. will get set and return to TOOL setting screen.