12-6
Error Messages in GP-GL Command Mode
Error
Displayed
LCD Display Cause Solution
E02001 The plotter received an unrecognizable
command.
Press the [ENTER] key.
Noise came in when the computer was
turned on.
Congure to drive the plotter from the menu
of the software.
The software conguration regarding the
output device has been changed.
Reset the interface settings of the software.
The plotter's interface conditions have
changed.
Reset the interface settings of the plotter.
E02004
A command was received containing
numeric parameters that exceed that
command's permissible range.
Congure to drive the plotter from the menu
of the software.
The software conguration regarding the
output device has been changed.
Reset the interface settings of the software.
The plotter's interface conditions have
changed.
Reset the interface settings of the plotter.
E02005
An error occurred in the receipt of data
within the interface.
Congure to drive the plotter from the menu
of the software.
The software conguration regarding the
output device has been changed.
Reset the interface settings of the software.
The plotter's interface conditions have
changed.
Reset the interface settings of the plotter.
E02006
The data out of cutting range has been
received.
Check the data.
Check the size of media and the cutting
range.
Check the magnication setting.
Check the step size settings.