DISTANCE ADJUST value corrects any deviation in the length of cut or plotted line segments, which occurs
depending on the media being used. DISTANCE ADJUST value for the deviation is specied as a percentage of
the total distance. For example, a setting of +0.05% adjusts a distance of 2 m (2,000 mm) by 2,000 x 0.05% = 1
mm, making 2,001 mm.
Supplement
This setting will be saved even if the power is shut off.
Operation
Supplement
Perform the settings in Normal menu.
1 Press the [COND/TEST] key.
CONDITION setting screen (1/3) is displayed.
2 Press [3] key (AREA).
AREA PARAMETERS setting screen (1/1) is displayed.
3 Press the [4] key (DISTANCE ADJUST).
DISTANCE ADJUST setting screen is displayed.
4 Press the [1] key (X).
X DISTANCE ADJUST setting screen is displayed.
Supplement
Setting range for adjustment value is -2.00%
to +2.00%.
Press the [FAST] key to change the setting
digits.
5 Press the POSITION ( ) key and increase or decrease the
setting value.