8-3
Connecting with RS-232C
The RS-232C settings can remember up to 8 different settings that can be switched if necessary.
Call up the setting to be used according to "Switching the user selection setting"
P. 8 - 4
, and then change and
save the RS-232C settings according to "Changing and saving the RS-232C interface setting"
P. 8 - 5
".
Setting user selection
Call up the user selection settings (CAD). "Command", "Origin point", "Step size", "Separator", "Timeout", "Page
length", and "Transfer conditions for RS-232C" have been set.
List of user selection settings
User selection settings
12345678
Command HP-GL HP-GL GP-GL HP-GL HP-GL HP-GL HP-GL HP-GL
Step size 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025
Origin point
LOWER
LEFT
CENTER LOWER
LEFT
LOWER
LEFT
LOWER
LEFT
CENTER CENTER CENTER
Separator PGNRJ0 SPPGSPNoneNone
Time out
0012012011000
Page length (mm) 1500 3000 1500 5000 3000 1500 5000 5000
Transfer conditions
9600N81X 9600N81X 9600N81X 9600N81X 9600N81X
19200N81X
9600N81X 9600N81X
Step pass –––––0––
Tool up speed –––––60 cm/s––
Cross cut –––––ON––
Cut line pattern
–––––OFF––
Space rear –––––12 mm––
: The current value is set.
User preference 6 is determined as per the following cutter pen conditions (all settings other than those listed
revert to default).
The settings other than the table are set to default value.
Condition No. Speed Acceleration Force Pen type
(Cutter blade)
Compensation value
(Offset)
160117 Pen
230114 09U 0
330114 09U 0
430114 09U 0
530114 09U 0
630114 09U 0
730114 09U 0
860114 09U 0