5-20
5-21
Supplement
When the value of the "SENSING LEVEL" is set
to a larger number, it will not sense the dust and
debris on the media surface, but setting it too
high might not allow the registration marks to be
detected. The dust and bumps on the media surface
might be detected as registration mark by mistake if
the value of the "SENSING LEVEL" is set to smaller
number.
5
Press the [1] key (X).
SENSING LEVEL X adjusting screen is displayed.
Supplement
Setting range is from 30 to 90.
6
Press the POSITION (
▲▼
) key and increase or decrease the
setting value.
POSITION
7
Confirm the setting and press the POSITION (
) key
(PREVIOUS).
POSITION
The value is entered and it will return to the SENSING LEVEL
adjusting screen.
8
Press the [2] key (Y).
SENSING LEVEL Y adjusting screen is displayed.
Supplement
Setting range is from 30 to 90.
9
Press the POSITION (
▲▼
) key and increase or decrease the
setting value.
POSITION
10
Confirm the setting and press the POSITION (
) key
(PREVIOUS).
POSITION
The value is entered and it will return to the SENSING LEVEL
adjusting screen.
Supplement
It will return to ARMS setting screen (4/4) without
changing the settings when you press the
POSITION (
) key (CANCEL).
11
Confirm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to ARMS setting screen (4/4).
12
Press the [MENU] key.
It will return to default screen.