4-4
Setting Cutting Width
Set the cutting width. It is possible to set that it will cut to the area outside of the push rollers, or not to cut at the
ends of the media.
Default setting is to the internal edge of the push rollers. It can be set up to 10 mm outside (positive value) or 10
mm inside (negative value) from the default position. The width will enlarge if the value is set to positive, and the
width will decrease if the value is set to negative. Setting will affect both ends, resulting the total width change
will be double the set value.
CAUTION
Do not set the "INITIAL BLADE CONTROL POSITION" of the special function to "OUTSIDE" when the setting value is set to more than 8 mm.
The blade might be damaged by moving the carriage outside the media under this condition.
Supplement
If the value is set to positive, it is able to cut over where the push rollers are, but the push rollers passes where it is cut, creating a chance of
bad feeding depending on the media.
Set the width of cutting area, and then send the cutting data to the plotter. Cutting data in the buffer memory will be cleared when cutting area
width is changed.
l
l
Next page
Supplement
See "How to Use Control Panel"
P.2-17
for
READY status.
1
Press the [MENU] key in READY status.
MENU screen is displayed.
2
Press the [3] key (AREA).
AREA PARAMETERS setting screen (1/2) is displayed.
3
Press the [1] key (EXPAND).
EXPAND LIMIT setting screen is displayed.
Supplement
Setting range is from +10 to -10 mm.
4
Press the POSITION (
▲▼
) key and increase or decrease the
setting value.