5-33
Setting the registration mark automatic detection
When setting the registration mark automatic detection to on, the following operations will be performed.
Set the registration mark mode to ARMS and during the start of the automatic reading when the current position
of the tool is close to the first point (Point 1), by pressing the "ENTER" key without moving to the detect start
position of tool, the registration mark position will be automatically retrieved.
*
The "Please move the tool and press ENTER" message will be displayed. Either press the "ENTER" key at that
tool position, or move the tool to a position close to the registration mark detect start position and press the
"ENTER" key.
Supplement
If the current position of the tool is distanced from the first registration mark, detection may take a long time, and errors due to not finding
anything may occur.
Next page
1
Press the [PAUSE/MENU] key.
MENU screen is displayed.
2
Press the [2] key (ARMS).
ARMS SETTING screen (1/4) is displayed.
3
Press the POSITION (
▲
) key twice.
ARMS SETTING screen (3/4) is displayed.
4
Press the [3] key (MARK AUTO SCAN).
MARK AUTO SCAN setting screen is displayed.