13-24
13
-
13-2513-25
Self Diagnostic Test
Operation status can be tested by self diagnostic test by operating the sensors and switches following the
instruction on the screen.
Supplement
Diagnostic test can be performed only right after the power is turned on. DIAGNOSTICS cannot be selected from the menu once any operation,
such as loading media, is performed.
Next page
Operation
1
Confirm that the power is turned off.
2
Turn the power on without loading the media.
3
Press the [MENU] key once the default screen is displayed.
MENU screen is displayed.
4
Press the POSITION (
) key (TEST).
POSITION
TEST menu screen (1/2) is displayed.
5
Press the [4] key (DIAGNOSTICS).
DIAGNOSTICS start screen is displayed.
6
Press the [1] key (CONTINUE).
Messages for testing are displayed on the screen.