5-31
Next page
6
Press the [2] key (SCAN).
Following message is displayed.
Supplement
The tool carriage will move faster when the [FAST]
key is pressed simultaneously with the POSITION
key.
7
Press the POSITION (
▲▼◄►
) key and move the tool carriage
to the area to start scanning of the registration mark.
Start position of registration mark scan
Feed direction of media
Align the tool to this area
Y
X
Supplement
It will return to ARMS setting screen (3/4) without
plotting when you press the [4] key (CANCEL).
8
Confirm the position of the tool, and if it is OK, press the [ENTER]
key.
The registration mark for comparison is plotted after scanning the registration
mark (see below). It will return to SENSOR OFFSET ADJ. screen once the
plotting is completed.
Feed direction of media
Registration mark
for comparison
Y
X
Registration mark
for adjustment
Distance adjustment value Y
Distance
adjustment
value X
Supplement
Position of the registration mark is measured at
the center of the line.
9
Using the scanned registration mark for adjusting, measure
the distance of how much the comparison registration mark
needs to be moved so both will overlap, and record the value.
As an example, in the figure above, it needs to move in negative
directions for both X and Y directions, so both of the adjustment
values will be a negative values.
10
Press the [3] key (X).
SENSOR OFFSET ADJ. X screen is displayed.