WE2107 - Communication commands
102
I1820-1.3 enHBM
Print strings
(Print strings for the print protocol)
Property Content Note
Command string PST
No. of parameters 2
Parameter range P1:= 0…2
P2:= string with 30 characters
Factory default empty string ""
Reaction time < 15 ms
Password protection No
Relevant to legal for
trade
No
Parameter backup With command TDD1
Input Master PST(P1)," P2 “; No response
Query Master PST(P1)?;
Response WE P2 crlf Max. 30 characters
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
The WE has three print strings (P1=0…2). All ASCII characters are allowed (20hex…7f hex)
for P2.
PST