WE2107 - Communication commands
138
I1820-1.3 enHBM
Clear total weight and counters
(Clear total weight and counters)
Property Content Comment
Command string CSN
No. of parameters
Parameter range
Factory default
Response time <15 ms
Password protection No
Relevant for legal for
trade
No
Parameter backup No data to back up
Master input CSN; No response
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
This command clears the total weight, the dosing counter, the dosing result and the print
counter:
SUM: = 0
NDS: = 0
FRS: = 0
PID: = 0
CSN