WE2107 - Communication commands
118
I1820-1.3 enHBM
3.13 Commands for setup the filling control /
limitswitches
For different applications the WE has implemented different functions:
D Application: platform scale (non automatic weighing indicator = NAWI)
D Application: process control (NAWI + 4 limit switches)
D Application: dosing control (portion weighing)
D Application: tank weighing (tank filling, portion weighing from the tank, emptying the tank)
The command SFU select the different functions for the different applications.
D Scale function SFU
D Limit switches LIV
For the dosing process control and tank weighing control there are the additional
commands:
D Start filling / dosing / emptying RUN
D Tare delay time TAD
D Residual flow time RFT
D Maximum filling / dosing time MFT
D Emptying time EPT
D Break filling / dosing / emptying BRK
D Dosing result FRS?
D Total weight (dosing) SUM?
D Dosing counter NDS?
D Clear total weight and counters CSN
Remarks:
Filling – fill a tank to a defined limit (max. filling level)
Dosing – fill a bin / vessel / bag from a tank (portion weighing)
Emptying – deflate the bin / tank ( for service purposes)