WE2107 - Communication commands
130
I1820-1.3 enHBM
Tare delay time
(Tare delay time portion weighing / dosing process)
Property Content Note
Command string TAD
No. of parameters 1
Parameter range P1=099999 [x 100 msec.] 0=disabled
Factory default 0
Reaction time <15 ms
Password protection Yes
Relevant to legal for
trade
NO
Parameter backup With command TDD1
Input Master TAD(P1); No response
Query Master TAD?;
Response WE P1crlf P1 = 6 characters
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
The resolution of this time parameter is 100 ms. After this delay time the WE perform a tare
and switch to NET value display/output.
TAD