EasyManua.ls Logo

HBM WE2107 - Emptying Time, Filling; Dosing Process

HBM WE2107
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
133
WE2107 - Communication commands
I1820-1.3 en HBM
Emptying time
(Emptying time, filling / dosing process)
Property Content Note
Command string EPT
No. of parameters 1
Parameter range P1=099999 [x 100 msec.] 0=disabled
Factory default 0
Reaction time <15 ms
Password protection Yes
Relevant to legal for
trade
NO
Parameter backup With command TDD1
Input Master EPT(P1); No response
Query Master EPT?;
Response WE P1crlf P1 = 6 characters
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
The resolution of this time parameter is 100 ms. If actual time exceeds this maximum
emptying time then all outputs will be deactivated (stops the emptying process).
EPT