51
WE2107 - Communication commands
I1820-1.3 en HBM
Linearization Measured values
(Input values linearization curve)
Property Content Note
Command string LIM
No. of parameters 2
Parameter range P1=1,2
P2=0... NOV (99999)
Value 1 or 2
Parameter
Factory default P2=0
Reaction time <15 ms
Password protection Yes
Relevant to legal for
trade
Yes
Parameter backup With command TDD1;
Input Master LIM(P1),(P2); No response
Query Master LIM(P1)?;
Response WE P2 crlf P2 = 6 characters
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
The values LIM are the input values of the linearization curve.
Conditions: 0 < LIM1 < LIM2 < NOV
For more information see command LIN
.
LIM