WE2107 - Communication commands
132
I1820-1.3 enHBM
Maximum filling time
(Maximum filling time, filling / dosing process)
Property Content Note
Command string MFT
No. of parameters 1
Parameter range P1=0…99999 [x 100 msec.] 0=disabled
Factory default 0
Reaction time <15 ms
Password protection Yes
Relevant to legal for
trade
NO
Parameter backup With command TDD1
Input Master MFT(P1); No response
Query Master MFT?;
Response WE P1crlf P1 = 6 characters
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
The resolution of this time parameter is 100 ms. If actual process time exceeds this
maximum filling time then all outputs (OUT1..3) will be deactivated (stops the process) and
the alarm / error will be activated.
MFT