113
WE2107 - Communication commands
I1820-1.3 en HBM
Button function long
(Button function long push (>5 sec))
Property Content Note
Command string BFL
No. of parameters 2
Parameter range P1: 1/2
P2: 0 15
Factory default 0
Reaction time < 15 ms
Password protection No
Relevant to legal for
trade
No
Parameter backup With command TDD1
Input Master BFL(P1),(P2); No response
Query Master BFL(P1)?;
Response WE P2 crlf 2 characters
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
This command defines the function of the buttons F1 and F2.
P1=1: button F1
P1=2: button F2
Parameter P2 defines the function. To activate this button function a long push (>5 sec.) is
necessary.