WE2107 - Communication commands
I1820-1.3 en HBM
Residual flow time
(Residual flow time, filling / dosing process)
Property Content Note
Command string RFT
No. of parameters 1
Parameter range P1=099999 [x 100 msec.] 0=disabled
Factory default 0
Reaction time <15 ms
Password protection Yes
Relevant to legal for
trade
NO
Parameter backup With command TDD1
Input Master RFT(P1); No response
Query Master RFT?;
Response WE P1crlf P1 = 6 characters
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
The resolution of this time parameter is 100 ms. If the valve is closed then residual material
flows into the tank/bin. So the WE waits this time before the next step will be performed.