WE2107 - Communication commands
134
I1820-1.3 enHBM
Break dosing / filling
(Break dosing / filling / emptying processes)
Property Content Note
Command string BRK
No. of parameters
Parameter range
Factory default
Reaction time < 15 ms
Password protection No
Relevant to legal for
trade
No
Parameter backup
Input Master BRK; No response
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
This command stops all processes immediately (deactivate OUT1..4).
BRK