WE2107 - Communication commands
I1820-1.3 en HBM
Start dosing
(Start dosing / portion weighing)
Property Content Note
Command string RUN
No. of parameters 1
Parameter range 0, 1, 2
Factory default 0
Reaction time < 15 ms
Password protection No
Relevant to legal for
trade
No
Parameter backup
Input Master RUN(P1); No response
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
This command starts the filling or dosing processes:
P1=0 Start portion weighing
P1=1 Start filling the tank (only if SFU=2/3)
P1=2 Start emptying the tank (only if SFU=2/3)
See description above.