WE2107 - Communication commands
126
I1820-1.3 enHBM
Scale Function
(Activate filling / dosing function)
Property Content Note
Command string SFU
No. of parameters 1
Parameter range P1=0,1,2, 3 0=disabled
Factory default 0
Reaction time <15 ms
Password protection Yes
Relevant to legal for
trade
NO
Parameter backup With command TDD1
Input Master SFU(P1); No response
Query Master SFU?;
Response WE P1crlf P1 = 1 character
Note: ( ) required parameters, < > optional parameters for parameter input
Function:
The command activate the filling function:
SFU0: normal operation (none automatic weighing instrument)
for the applications platform scale and process control.
SFU1: filling function with additive weighing (only filling process)
SFU2: filling function with subtractive weighing (tank weighing)
SFU3: filling function with subtractive weighing (tank weighing)
SFU