Diagnostics > Status Configuration > Security Status
Diagnostics
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
427
Table
Parameters Meaning
Password default
settings unchanged
Activates/deactivates the monitoring of the password for the locally set up
user accounts
user
and
admin
.
Possible values:
marked
(default setting)
Monitoring is active.
The "Security Status" changes to "Error" if the password for the
user
or
admin
user accounts is the default setting.
unmarked
Monitoring is inactive.
You set the password in the
Device Security > User Management
dialog.
Minimum Password
Length < 8
Activates/deactivates the monitoring of the "Minimum Password Length"
policy.
Possible values:
marked
(default setting)
Monitoring is active.
The "Security Status" changes to "Error" if the value for the "Minimum
Password Length" policy is less than
8
.
unmarked
Monitoring is inactive.
You specify the "Minimum Password Length" policy in the
Device
Security > User Management
dialog in the "Configuration" frame.
Password Policy
settings deactivated
Activates/deactivates the monitoring of the Password policies settings.
Possible values:
marked
(default setting)
Monitoring is active.
The "Security Status" changes to "Error" if the value for at least one of
the following policies is less than
0
.
Minimum Upper Cases
Minimum Lower Cases
Minimum Numbers
Minimum Special Characters
unmarked
Monitoring is inactive.
You specify the policy settings in the
Device Security > User Management
dialog in the "Password Policy" frame.