Diagnostics > Status Configuration > Security Status
Diagnostics
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
429
Access to System
Monitor with V.24
possible
Activates/deactivates the monitoring of the system monitor.
When the system monitor is activated, the user has the possibility to
change to the system monitor via a V.24 connection.
Possible values:
marked
Monitoring is active.
The "Security Status" changes to "Error" if you activate the system
monitor.
unmarked
(default setting)
Monitoring is inactive.
You activate/deactivate the system monitor in the
Diagnostics >
System
> Selftest
dialog.
Saving the
Configuration
Profile on the
External Memory
possible
Activates/deactivates the monitoring of the configuration profile in the
external memory.
Possible values:
marked
Monitoring is active.
The "Security Status" changes to "Error" if you activate the saving of
the configuration profile in the external memory.
unmarked
(default setting)
Monitoring is inactive.
You activate/deactivate the saving of the configuration profile in the
external memory in the
Basic Settings > External Memory
dialog.
Load unencrypted
config from external
memory
Activates/deactivates the monitoring of loading unencrypted configuration
profiles from the external memory.
Possible values:
marked
(default setting)
Monitoring is active.
The "Security Status" changes to "Error" when the settings allow the
device to load an unencrypted configuration profile from the external
memory.
The "Signal Contact Status" frame in the
Basic Settings > System
dialog, displays an alarm if the following preconditions are fulfilled:
The configuration profile stored in the external memory is
unencrypted.
and
The "Config Priority" field in the
Basic Settings > External
Memory
dialog has the value
first
or
second
.
unmarked
Monitoring is inactive.
Parameters Meaning