Basic Settings > Load/Save
Basic Settings
RM GUI HiSecOS EAGLE20/30
Release
3.0
09/2015
47
Undo Modifications of Configuration
Parameters Meaning
Operation When a user enables the function, the device continuously checks
whether it can still be reached from the IP address of the user. If the
connection is lost, after a specified time period the device loads the
“Selected” configuration profile from the non-volatile memory (
NVM
).
Afterwards, the device can be accessed again.
Possible values:
"On"
Function is enabled.
– You specify the time period between the loss of the connection
and the loading of the configuration profile in the field "Period to
undo while Connection is lost [s]".
– If the non-volatile memory (
NVM
) contains multiple configuration
profiles, the device loads the configuration profile designated as
“Selected”.
"Off" (default setting)
Function is disabled.
Switch the function off again before you close the graphical user
interface. You thus prevent the device from restoring the configuration
profile designated as “Selected”.
Note: Before you enable the function, save the settings in the
configuration profile. Current changes, that are saved temporarily, are
therefore maintained in the device.
Period to undo while
Connection is lost
[s]
Specifies the time in seconds after which the device loads the “Selected”
configuration profile from the non-volatile memory (
NVM
) if the connection
is lost.
Possible values:
30..600
(default setting:
600
)
Specify a sufficiently large value. Take into account the time when you are
viewing the dialogs of the graphical user interface without changing or
updating them.
Watchdog IP
Address
Displays the IP address of the PC on which you have enabled the function.
Possible values:
IPv4 address (default setting:
0.0.0.0
)