Figure 4-51 Power off procedure for SMP blade
(B) Press and release the Power switch within one second
This procedure initiates a remote shutdown of applications and OS before the
server blade becomes standby mode.
1. Ensure that Power LED lights in green.
2. Press and release the Power switch within one second. The OS starts the
shutdown.
3. Ensure that the shutdown was completed and Power LED blinks in green.
(C) Press and hold the Power switch for four seconds or more
This procedure forces the server blade to move to standby mode without
shutdown of applications and OS. You should perform this procedure when
the server blade stopped responding only.
1. Ensure that Power LED lights in green.
2. Press and hold the Power switch for four seconds or more. The Power LED
turns blink in green.
3. Release the Power switch.
4-60
Common process for replacement
Hitachi Compute Blade 500 Series System Service Manual