EasyManua.ls Logo

Hitachi CB 520H B3 - Page 353

Hitachi CB 520H B3
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. Server model
# of CNA
1
# of CTRL
2
Controller #
#2, #3 for Mezz #2
#4, #5 for Mezz #4
Notes:
1. The # of CNA indicates the total number of installed Emulex 10Gb CNA
mezzanine card and LAN mezzanine card.
2. Confirm the indicated number of controllers in Controller Selection Menu window
is equal to the # of Controller indicated in this table for the replaced server
configuration.
3. The controller #0 for is assigned to LOM for CB 520H B1 (GGAGC0Bn- with
LOM).
4. The controller #0 and #1 are assigned to LOMs for CB 540A B1 (GGAGD0Bn-
with LOM).
Note: The Personality for Emulex 10Gb LAN mezzanine card and LOM is
fixed to NIC by default and cannot change.
7. Port Selection menu window is displayed. Select the port#0, and then
press Enter key.
8. MultiChannel Configuration window is displayed. Confirm and record
the configuration of PXE Boot Support.
9. If PXE Boot Support is Enabled, confirm and record Bandwidth and
LPVID.
Configuring Emulex mezzanine card
7-59
Hitachi Compute Blade 500 Series System Service Manual

Table of Contents

Other manuals for Hitachi CB 520H B3

Related product manuals