27. Static IP Address window is displayed. Set up IP Address, Subnet
Mask and Default Gateway for the replaced card corresponding to the
ones of the failed card that you recorded in the previous procedures.
28. Select Save, and then press Enter.
Note: When the following error messages are indicated after setting
Static IP Address, return to Static IP Address dialog box by pressing
any key, and then set again the correct parameters.
1. The following message is indicated when the last dot address of IP
Address or Default Gateway Address is set to 0, the cursor is moved
onto Save, and then Enter is pressed.
2. The following message is indicated when the first dot address of IP
Address or Default Gateway Address is set to 0, the cursor is moved
onto Save, and then Enter is pressed.
3. The following message is indicated when the dot address of Subnet
Mask is not set to 0 or 255, the cursor is moved onto Save, and then
Enter is pressed.
29. Controller Configuration window is displayed. Select iSCSI Target
Configuration, and then press Enter.
30. iSCSI Target Configuration window is displayed. Select Add New
iSCSI Target, and then press Enter.
31. Static IP Address window is displayed. Set up iSCSI Target Name,
iSCSI Target IP Address, TCP Port Number and Boot Target for the
replaced card corresponding to the ones of the failed card that you
recorded in the previous procedures.
32. Select Save/Login, and then press Enter.
7-88
Configuring Emulex mezzanine card
Hitachi Compute Blade 500 Series System Service Manual