Note: The iSCSI Initiator Name may not be fully indicated in the dialog
box.
Move cursor to right by using → key to confirm the last character.
21. Controller Selection menu window is displayed. Select the port#0, and
then press Enter.
22. Controller Configuration window is displayed. Select Controller
Properties, and then press Enter.
23. Controller Properties window is displayed. Set up Boot Support for
the replaced card corresponding to the ones of the failed card that you
recorded in the previous procedures.
24. Select Save, and then press Enter.
25. Controller Configuration window is displayed. Select Network
Configuration, and then press Enter.
26. Network Configuration window is displayed. Select Configure Static
IP Address, and then press Enter.
Configuring Emulex mezzanine card
7-87
Hitachi Compute Blade 500 Series System Service Manual