SCPI
COMMAND SUMMARY
l
POWer:STEP:AUTO
ONlOFFlllO
l
POWer:STEP:AUTO?
Sets and queries the function switch that controls how the power step
size (POWer:STEP:INCRement)is determined.
If
in the automatic
state, then the step size is 1 dB. The *RST setting is ON.
l
POWer:STEPC:INCRementl
<num>CDB]
IMAXimumlMINimum
l
POWer:STEP[:INCRementl?
CMAXimum
I
MINimum]
Sets and queries the power step size to be used for any node in the
power subsystem that allows UP and DOWN as parameters. Setting this
value explicitly
causes POWer:STEP:AUTO OFF.
The *RST setting is 10 dB.
l
POWer:STOP
Cnum>[lvl
suffix]
lMAXimumlMINi.mumlUPlDOWN
l
POWer:STOP?
[MAXimumlMINimum]
Sets and queries the ending power for a power sweep. Default units
and units for query response are determined by the command
UNIT:POWer.
The
coupling equations for power sweep are exactly
analogous to those for frequency sweep. Power sweep is allowed to be
negative, unlike frequency sweeps. *RST value is 0
dBm.
l
PULM:EXTernal:DELay
<num>[time
suffix]
lMAXimumlMINimum
l
PULM:EXTernal:DELay?
[MAXimumIMINimum]
Sets and queries the value of pulse delay from the time the external
pulse signal arrives to when the video pulse is generated. The
minimum value is 225 ns. After *RST the value is
MINimum.
l
PULM:EXTernal:POLarityNORMalIINVerted
a
PULM:EXTernal:POLarity?
Selects the polarity of the external pulse signal.
NORMal
causes
the positive-going edge of the signal to trigger the internal pulse
generator and to turn on the RF. After *RST the value is NORMal.
l
PULM:INTernal:FREQuency
<num>[freq
suffix]
IMAXimumlMINimum
l
PULM:INTernal:FREQuency?
[MAXimumlMINimum
Sets and queries the frequency of the internal pulse generator.
The *RST value is 500 kHz.
l
PULM:INTernal:GATE
ONlOFFlllO
l
PULM:INTernal:GATE?
Sets and queries the state of the internal pulse generator’s gating
control. When ON, and the pulse trigger source is internal, the
external pulse input is used to gate the pulse generator. When pulse
trigger source is external, this switch is ignored and no gatingis
possible. After
*RST,
the setting is 0.
Operating and Programming Reference S-45