SCPI
COMMAND SUMMARY
l PULM:INTernal:PERiod Cnum>[time suffix]
1MAXimumlMINimum
l
PULM:INTernal:PERiod? {MAXimumlMINimum]
Sets and queries the period of the internal pulse generator.
The *RST value is 2
pus.
l PULM:INTernal:TRIGger:SOURce
INTernallEXTernal
l
PULM:INTernal:TRIGger:SOURce? [MAXimumlMINimum]
Sets and queries the setting of the internal pulse generator’s trigger
source. When
INTernal,
pulse period and frequency determine the
repetition rate of the pulse train. When in
EXTernal,
the repetition
rate is set by the EXT PULSE in jack. After
*RST,
the value is
INTernal.
l PULM:INTernal:WIDTH
<num>(time
suffix]
1MAXimumlMINimum
l
PULM:INTernal:WIDTH? [MAXimumlMINimum]
Sets and queries the width of the internal pulse generator. The
"RST
value is 1 ps.
Pulse Subsystem
Since frequency and period are inversely related, if both are sent
in the same message, only the last one is applied. If the
WIDth
command and either the
FREQuency
or PERiod command are sent
in the same message, they must be accepted without error if the
resulting pulse is possible.
l PULSe:FREQuency
<num>[freq
suffix]
1MAXimumlMINimum
l
PULSe:FREQuency? [MAXimumlMINimum]
Sets and queries the frequency of the internal pulse generator. The
resolution of the frequency is such that the resulting period is set to a
resolution of 1 ps. The *RST value is 500 kHz.
l PULSe:PERiod
<num>[time
suffix]
1MAXimumlMINimum
l
PULSe:PERiod? [MAXimumlMINimum]
Sets and queries the period of the internal pulse generator. The
resolution of this is 1 ps. The *RST value is 2 ps.
l PULSe:WIDTh Cnum>[time suffix]
IMAXimumlMINimum
l
PULSe:WIDTh? [MAXimumlMINimum]
Sets and queries the width of the internal pulse generator. The *RST
value is 1
~.ls.
l PULM:SLEW
Cnum>Ctime
suffix]
1MAXimumlMINimum
l
PULM:SLEW? [MAXimumlMINimum]
Sets and queries the rise time for the pulse modulation. The typical
usage is MAX I MIN since calibrating the rise time of the pulses is not
common. Slow pulse is set by the command PULS:SLEW MAX. Any
value above 1.8 ps is set to maximum. The *RST setting is MIN.
S-46 Operating and Programming Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 8360 B Series and is the answer not in the manual?

HP 8360 B Series Specifications

General IconGeneral
BrandHP
Model8360 B Series
CategoryPortable Generator
LanguageEnglish

Related product manuals