127
Troubleshooting MPLS TE
No TE LSA generated
Symptom
OSPF TE is configured but no TE LSAs can be generated to describe MPLS TE attributes.
Analysis
For TE LSAs to be generated, at least one OSPF neighbor must reach FULL state.
Solution
1. To resolve the problem:
a. Use the display current-configuration command to verify that MPLS TE is configured on
involved interfaces.
b. Use the debugging ospf mpls-te command to verify that OSPF can receive the TE LINK
establishment message.
c. Use the display ospf peer command to verify that OSPF neighbors are established
correctly.
2. If the problem persists, contact Hewlett Packard Enterprise Support.